Vitocal 150-A – air source heat pump 01
Air-Source Heat Pump

Air source heating with a compact monoblock design

Vitocal 150-A uses outdoor air as an energy source for home heating and cooling.

Convenient operation with ViCare

High energy efficiency

Simpler installation with a pre-plumbed indoor unit

Heating and cooling in one system

Interested in getting a quote or would like more information?

Output for changing heating demand

Rated heating output from 2.6 to 14.9 kW.

Designed for heating upgrades

Flow temperatures up to 70 °C at outdoor temperatures down to −10 °C support modernisation projects.

Climate Protect+++

Natural R290 propane refrigerant has a GWP100 of 0.02.

Reliable efficiency with OptiPerform

A patented hydraulic arrangement supports dependable, efficient operation.

Efficient use of electricity

COP up to 5.0 at A7/W35, measured to EN 14511.

A more compact installation

The system requires up to 60% less space than comparable systems.

Comfort across the seasons

The same system provides room heating and cooling.

Energy use in view

Integrated energy management helps make consumption and costs easier to understand.

Control from your phone

Use ViCare for convenient everyday operation.

Key features:

Vitocal 150-A for efficient home heating upgrades

Make use of energy from the outdoor air for heating and cooling with a compact monoblock heat pump. Vitocal 150-A combines efficient performance, app control and a considered design.

Developed with modernisation in mind, it provides flow temperatures up to 70 °C. Existing radiators can continue to be used, so underfloor heating is not essential for the upgrade.

Climate Protect+++ and natural refrigerant

The Vitocal 15x range uses R290 propane refrigerant with a GWP100 of 0.02. The Climate Protect label is based on the TEWI (total equivalent warming impact) indicator, which considers the appliance’s lifecycle efficiency together with the refrigerant’s global warming potential.

OptiPerform with Hydro AutoControl

The patented hydraulic system and Hydro AutoControl® help the heat pump operate reliably and efficiently throughout its service life. The design simplifies and speeds up contractor setup, helping reduce installation costs. It also takes up to 60% less space than comparable systems.

Connected support through ViCare and ViGuide

ViCare makes heating control intuitive and uses a green status indicator to show when the system is working normally.

ViGuide gives trade partners tools to monitor and control systems in standalone homes and apartment buildings, with access to Technical Service.

Energy information on your mobile device

Check household energy flows in real time on a smartphone or tablet. Energy Management through ViCare helps identify opportunities to lower energy bills and conserve resources. Explore compatible systems and commissioning information.

One connected platform with Viessmann One Base

Viessmann One Base links compatible devices and digital applications into an expandable household climate and energy system. Use one app to follow electricity and heat use, monitor running costs and coordinate efficient operation with a lower carbon footprint.

The platform connects digital services with heat pumps, battery storage and photovoltaic systems. The free ViCare app provides the user interface, supported by integrated Energy Management. A connected contractor can also identify irregularities and make suitable corrections remotely, eliminating unnecessary travel and appointments.

Explore Viessmann One Base.

Product Details:

Product Details Title Product Details Content
Energy efficiency class, DHW heating

–

Application area

Detached houses, modernisation projects

Operation

Heat pump control unit with 7 inch colour touchscreen, operation via ViCare app possible

DHW heating

Additional DHW cylinder required, resulting in a high level of DHW convenience.

Additional features

For room heating/cooling and DHW heating | Maximum flow temperature: 70 °C (at an outside temperature of down to ––10 °C) | Monoblock indoor unit with heat pump control unit, high efficiency circulation pump for the secondary circuit, 4/3-way valve, safety assembly | Integral instantaneous heating water heater | Integral heating water buffer cylinder and overflow valve

Voltage

Vitocal 150-A AWO-M-E-ACI (-AF) : 230 V | Vitocal 150-A AWO-E-ACI (-AF) : 400 V

Rated heating output (kW) according to EN 14511, nominal heat output
  • Operating point A7/W35: Type 150.A10: 7.3 kW | type 150.A13: 8.1 kW | type 150.A16: 9.1 kW
  • Operating point A-7/W35: Type 150.A10: 9.7 kW | type 150.A13: 11.1 kW | type 150.A16: 12.4 kW
Rated heating output according to EN 14511 (A7/W35, spread 5 K)
  • Nominal heat output coefficient of performance ε (COP) in heating mode: Type 150.A10: 5.0kW | type 150.A13: 4.9kW | type 150.A16: 4.9kW
  • Output range: 2.6-12.0 kW | type 150.A13: 3.0-13.4 kW | type 150.A16: 3.3-14.9 kW
Sound power level
  • 56 dB(A)
  • *Measurement of the sound power level in accordance with EN ISO 12102/EN ISO 9614-2, accuracy class 3 in night mode.
Cooling performance data according to EN 14511 (A35/W18, spread 5 K)
  • Cooling capacity: Type 150.A10: 9.6 kW | type 150.A13: 11.0 kW | type 150.A16: 13.2 kW
  • EER coefficient of performance: Type 150.A10: 4.4 | type 150.A13: 4.0 | type 150.A16: 3.7
  • Cooling capacity max.: Type 150.A10: 14.4 kW | type 150.A13: 15.7 kW | type 150.A16: 17.0 kW
Refrigeration circuit
  • Refrigerant: R290
  • Filling quantity as delivered: 2.0 kg
  • Global warming potential (GWP100 acc. to IPPC AR6): 0.02
  • CO2 equivalent: 0.00004t
Dimensions (Length x width x height) in mm
  • Indoor unit (Type 150.A10): 360mm x 450mm x 920mm
  • Outdoor units (Type 150.A13 | type 150.A16): 600mm x 1144mm x 1382mm
Weight (indoor unit)

47 kg

Weight (outdoor unit)

191 kg

Energy efficiency ƞs at W35 in %
  • Type 150.A10: 190 | type 150.A13: 178 | type 150.A16: 178
  • *Heating performance data in line with Commission Regulation (EU) No 813/2013 under average climatic conditions for medium temperature application (W55).
Energy efficiency ƞs at W55 in %
  • Type 150.A10: 145 | type 150.A13: 141 | type 150.A16: 141
  • *Heating performance data in line with Commission Regulation (EU) No 813/2013 under average climatic conditions for medium temperature application (W55).
Product cross-section, indoor unit
  • Heating water buffer cylinder (16 litre capacity)
  • Diaphragm expansion vessel (10 litre capacity)
  • 4/3-way valve for central heating/DHW heating/bypass
  • Safety valve
  • Instantaneous heating water heater
  • Secondary pump (high efficiency circulation pump)
  • Heat pump control unit with 7 inch colour touchscreen
Product cross-section, outdoor unit
  • Coated evaporator
  • Power saving, variable speed DC fan
  • Power saving, variable speed DC fan
  • Inverter-controlled compressor
  • Inverter
  • Condenser

Product Downloads:

ViBooks - documentation, manuals, and instructions

In our ViBooks database, you can find the operating, installation, and service instructions you need, as well as technical guides, price sheets, printed marketing materials, and many other documents for your Viessmann products.

Warranty Information:

Whether stainless steel radial heat exchangers, stainless steel cylinder or components in the Vitodens 100-W: Viessmann products are characterised by their outstanding quality, resource-preserving technology and maximum efficiency. Which is why we offer a guarantee of up to 5 years on boiler components and 10 years on radial heat exchanger (subject to terms and conditions).

Online warranty registration

Register your product warranty online and enjoy a comprehensive coverage and after-sales service for your products.