How often does a heating system need to be serviced? Does Viessmann take care of maintenance of the heating system? What temperature should I run my heating system at? What should you do if you get an error message? Here you will find the answers to these and other frequently asked questions we get asked.
Does heating need to be on during the summer?
This aspect relates primarily to the relationship between tenant and landlord. The summer months are not part of the actual heating period. However, since this is not governed by law, the question of whether or not heating is required depends on several things, including the outside temperature. If the temperature turns too cold in the apartment or house and does not increase for several days, the heating will need to be switched back on again. As a homeowner, you can decide when the heating should be on or off.
Ideally, how warm should it be in the rooms?
A comfortable temperature is something that is very individual – some people need it a little warmer, whereas others do better with cooler temperatures. Nevertheless, there are some guideline values for the optimal room temperature for orientation. These are as follows for different parts of the home:
When should you start heating?
There is no legally prescribed point in time from which landlords must provide heat and generally speaking, heating periods are not defined in law. Nevertheless, the period between June to August has become firmly established as the typical heating period. As such, June is considered to be the starting point in many places. However, outdoor temperatures and minimum room temperatures play a much more central role than the date.
What is the optimum flow temperature?
There is no generally valid ideal flow temperature. The ideal flow temperature depends on many factors, such as the energy condition of the building as well as of the heating system itself, the type and size of the heating surfaces and the type of heating system installed. The flow temperature should therefore match the house and the heating behaviour of its occupants. After all, excessively high flow temperatures cause high heating costs. If the flow temperature is too low, it will remain uncomfortably cool in the house. It is best to seek advice from a Viessmann trade partner, who can not only determine the correct values for hydronic balancing, but can also help you to set the optimum flow temperature.
Why is regular heating maintenance important?
Regular maintenance and thus appropriate care not only helps to maintain the functional and operational reliability of your heating system, but also its value. The burner, boiler and control unit should be inspected once a year. Regular inspection and maintenance will extend the service life of your heating system and ensure its safe and efficient operation. This will mean that the energy used is used as effectively as possible and as cleanly as possible. This helps to protect the environment and save heating costs.
How often does the heating system need to be serviced?
A heating system runs at full load for three to five months of the year. Therefore, heating system maintenance should be carried out regularly. This way, you can be certain that it will work properly for a long time. However, there are no legal regulations in this regard. In practice, a cycle of twelve months has become established practice for most types of heating system. An annual inspection is therefore recommended. In addition, you can also conclude a maintenance contract. That way, you will never have to worry about having your heating system serviced.
Does Viessmann carry out heating system maintenance on behalf of system operators?
When does hydronic balancing need to be carried out?
Does hydronic balancing need to be repeated at regular intervals?
Can you carry out hydronic balancing yourself?
What is a heating system check and when should one be carried out?
A heating system check determines the optimisation and savings potential of a heating system. To do this, a heating contractor will thoroughly examine the heating system and uncover weak points that reduce energy efficiency. The result is a qualitative energy assessment of the heating system in the form of a report. When a heating system check needs to be carried out is not prescribed by law. Nor is there any need to out checks at regular intervals. It is more about where there is room for improvement. At best, you should have your heating system checked in summer or autumn. There is then enough time to complete the necessary measures before the start of the next heating period.
Why does the heating need to be vented?
What needs to be borne in mind during thunderstorms and lightning strikes?
If there is damage to the heating system as a result of a thunderstorm or lightning strike, all live components must be replaced in case of doubt. An expert will need to carry out an assessment. Neither Viessmann itself nor the heating contractor can act as an expert. The costs that will be covered will depend on the insurance contract that you have in place. Depending on the case in question, the contract may be a contents, buildings or natural hazards insurance policy.
How can you protect the heating system from lightning?
Viessmann control technology complies with the regulations and standards for interference immunity. In addition, the use of lightning conductors or lightning current arresters may also be useful. The individual units themselves are also equipped with fine protection. With this, the interference factors are directly discharged via a protective earth conductor.
What needs to be done after a storm and flooding?
What should you do if you get an error message?
Where can I find the serial number and year of manufacture of my Viessmann heating system?
You will find the serial number on the device itself. There will be a barcode sticker with a 16-digit number. If you are unable to locate this sticker, you can also ask your Viessmann heating contractor. The year of manufacture can be found on the type plate of the boiler or in report from the flue gas inspector. If you would like to know how old your Viessmann heating system is, the 16-digit number can help you –– just look at the eighth digit.
If I have to bleed the radiators several times a year, does this mean that there is a fault?
What should you do in the event of a burner fault?
What is the best way to adjust the heating system in summer?
A heating system should run in summer mode during the warmer months of the year. This is both efficient and, if your boiler provides heating water as well as domestic hot water, ensures domestic hot water heating. Modern models also allow you to set room and outside limit temperatures. This way you ensure that the system starts up on cooler days in spring or summer, but not on every cool morning.
What should you do with your heating during the holiday season?
In order to save energy, it can make sense to switch off domestic hot water heating during the summer holiday period. If you have a decentralised domestic hot water heating system, this is simple and usually pays off, particularly if it is a rather small storage facility. However, larger cylinders with a capacity of between 250 and 300 litres should only be completely shut off when you are not likely to be at home for several weeks. This is because heating up a cooled-down cylinder of this size consumes a lot of energy, among other things.
How do you top up heating water?
There are a number of reasons why a system owner might need to top up the water in a Viessmann heating system. A heating water pressure that is too low may be an indication of this. Other signs include radiators remaining cold or annoying noises possibly caused by trapped air bubbles.
There are a few things to bear in mind when it comes to tipping up a heating system correctly. In addition to the instructions in the operating instructions, pay particular attention to the water quality. The heating water should comply with both the Drinking Water Ordinance [Germany] and the VDI Guideline 2035 in order to avoid damage to the system due to contamination and deposits.
The following steps must be followed:
If in doubt, contact one of our Viessmann trade partners.
Where does the fuel cell heating system get the hydrogen from?
The hydrogen for cold combustion in a fuel cell heating system comes from natural gas. This consists to a large extent of methane, which in turn is composed of carbon and hydrogen. A reformer is needed to separate these two elements from one other – in the process, hydrogen and carbon dioxide are produced by means of water vapour.
Why replace a 20 year old heating system if it works perfectly?
It is advisable to replace a boiler after 15 to 20 years at the latest. This is because outdated heating technology consumes a comparatively large amount of energy, especially if the models are gas or oil heating systems without condensing technology. New models increase efficiency, reduce fuel use and lower heating costs. Modernisation can provide added security.
Who will explain the different functions of the heating system after installation?
The heating contractor who installs the heating system will show you how the heating system works after the work has been completed. In addition to demonstrating the correct operation, they will also give you instructions on what to do in the event of fault messages or what to consider when setting the heating curve.
Whatever your question is, we’ll have an answer. Please feel to get in touch with our friendly team and let us know how we can help you.